    Status assessment of transformer windings via on-line stray inductance measurement

  • Author

    Arri, E. ; Mocci, F. ; Tosi, M.

  • Author_Institution
    Dipartimento di Autom. e Inf., Politecnico di Torino, Italy
  • fYear
    1994
  • fDate
    10-12 May 1994
  • Firstpage
    1171
  • Abstract
    Power transformer windings must be able to withstand the electrodynamic stresses caused by external short-circuits. One technique for detecting permanent deformations in winding geometry (and any related conductor insulation damage) due to these effects consists in using the transformer stray inductance as a diagnostic sensor. Should the variations of this inductance be more than 5 or 6 percent (compared to the rated value), the transformer is considered faulty. Measurements of stray inductance are normally performed by means of a specially devised Maxwell bridge, but only in out-of-service-condition. A voltamperometric method has recently been suggested for on-line monitoring this inductance with precision at least of the same order via an intelligent system, thus permitting the real-time diagnosis, without service interruptions, of the state of the transformer windings and immediate shutdown when necessary. The method employs a data acquisition system with high-speed simultaneous sampling on two or more channels, depending on the transformer phases. Further positive tests were performed on a 250 MVA three-phase autotransformer. This paper presents an ultimate improvement of the method that, by means of a special procedure, allows to obtain automatically a correct adjustment of the system without the need to set the transformer in no-lend condition. So, the proposed technique proves suitable for inclusion in a new and more general on-line control procedure for power transformer protection and service management
  • Keywords
    automatic test equipment; automatic testing; compensation; computerised instrumentation; deformation; inductance measurement; power transformer testing; transformer windings; Maxwell bridge; conductor insulation damage; diagnostic sensor; electrodynamic stresses; external short-circuits; online control; online stray inductance measurement; permanent deformations; power transformer protection; power transformer windings; service management; three-phase autotransformer; transformer stray inductance; transformer windings; voltamperometric method; winding geometry; Bridge circuits; Conductors; Electrodynamics; Geometry; Inductance measurement; Performance evaluation; Power transformer insulation; Power transformers; Stress; Windings;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1994. IMTC/94. Conference Proceedings. 10th Anniversary. Advanced Technologies in I & M., 1994 IEEE
  • Conference_Location
    Hamamatsu
  • Print_ISBN
    0-7803-1880-3
  • Type

    conf

  • DOI
    10.1109/IMTC.1994.351846
  • Filename
    351846