DocumentCode :
233877
Title :
Dual loop control for eliminating DC-bias in a DC-DC dual active bridge converter
Author :
Baddipadiga, Bhanu Prashant ; Ferdowsi, M.
Author_Institution :
Electr. & Comput. Eng., Missouri Univ. of Sci. & Technol., Rolla, MO, USA
fYear :
2014
fDate :
19-22 Oct. 2014
Firstpage :
490
Lastpage :
495
Abstract :
In bi-directional dual active bridge (DAB) converters, non-ideal behavior of the system components can lead to dc bias in the converter which results in magnetic saturation of the high frequency transformer. This paper proposes adding an extra control loop to overcome this problem. A simulation model has been developed to compare the operation of the converter with ideal and non-ideal components. The results with the extra loop applied to eliminate dc offsets have been shown. Experimental results have been presented to support the simulation results.
Keywords :
DC-DC power convertors; bridge circuits; electric current control; high-frequency transformers; DAB converter; DC offset elimination; DC-DC dual active bridge converter; DC-bias elimination; dual loop control; high frequency transformer; magnetic saturation; Bridge circuits; Circuit faults; Control systems; Magnetic flux; Phase modulation; Saturation magnetization; Voltage control; dc-bias; dual loop control; magnetic saturation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Renewable Energy Research and Application (ICRERA), 2014 International Conference on
Conference_Location :
Milwaukee, WI
Type :
conf
DOI :
10.1109/ICRERA.2014.7016433
Filename :
7016433
Link To Document :
بازگشت