• DocumentCode
    2338923
  • Title

    Implementation of signaling tunnel in the GMPLS control plane

  • Author

    Korniak, Janusz ; Rozycki, Pawel

  • Author_Institution
    Autonomous Dept. of Electron. & Telecommun., Univ. of Inf. Technol. & Manage., Rzeszow
  • fYear
    2008
  • fDate
    25-27 May 2008
  • Firstpage
    989
  • Lastpage
    993
  • Abstract
    The reliability of the GMPLS control plane is discussed in the paper. The protection of signaling link can improve significantly reliability level of the control plane and therefore overall GMPLS reliability. The signaling tunnel in the control plane can be implemented with the use of MPLS technology. This approach has been implemented in the simulation environment and verified. The results confirm efficiency of that solution.
  • Keywords
    multiprotocol label switching; telecommunication links; telecommunication network reliability; telecommunication signalling; GMPLS control plane; reliability; signaling link; signaling tunnel; Hardware; IP networks; Information management; Information technology; Multiprotocol label switching; Packet switching; Protection; Technology management; Telecommunication control; Wire; GMPLS; reliability; simulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Human System Interactions, 2008 Conference on
  • Conference_Location
    Krakow
  • Print_ISBN
    978-1-4244-1542-7
  • Electronic_ISBN
    978-1-4244-1543-4
  • Type

    conf

  • DOI
    10.1109/HSI.2008.4581579
  • Filename
    4581579