DocumentCode :
2338923
Title :
Implementation of signaling tunnel in the GMPLS control plane
Author :
Korniak, Janusz ; Rozycki, Pawel
Author_Institution :
Autonomous Dept. of Electron. & Telecommun., Univ. of Inf. Technol. & Manage., Rzeszow
fYear :
2008
fDate :
25-27 May 2008
Firstpage :
989
Lastpage :
993
Abstract :
The reliability of the GMPLS control plane is discussed in the paper. The protection of signaling link can improve significantly reliability level of the control plane and therefore overall GMPLS reliability. The signaling tunnel in the control plane can be implemented with the use of MPLS technology. This approach has been implemented in the simulation environment and verified. The results confirm efficiency of that solution.
Keywords :
multiprotocol label switching; telecommunication links; telecommunication network reliability; telecommunication signalling; GMPLS control plane; reliability; signaling link; signaling tunnel; Hardware; IP networks; Information management; Information technology; Multiprotocol label switching; Packet switching; Protection; Technology management; Telecommunication control; Wire; GMPLS; reliability; simulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Human System Interactions, 2008 Conference on
Conference_Location :
Krakow
Print_ISBN :
978-1-4244-1542-7
Electronic_ISBN :
978-1-4244-1543-4
Type :
conf
DOI :
10.1109/HSI.2008.4581579
Filename :
4581579
Link To Document :
بازگشت