Title :
Factor analysis for quantitation of myocardial blood flow (MBF) using 13N-ammonia dynamic PET imaging
Author :
Wu, Hsiao-Ming ; Hoh, Carl K. ; Buxton, Denis B. ; Schelbert, Heinrich R. ; Choi, Yong ; Hawkins, Randall A. ; Phelps, Michael E. ; Huang, Sung-Cheng
Author_Institution :
Sch. of Med., California Univ., Los Angeles, CA, USA
fDate :
30 Oct-5 Nov 1994
Abstract :
Regional myocardial blood flow (MBF) can be measured by 13 N-ammonia PET dynamic imaging using the conventional modeling approach that requires blood sampling, region-of-interest (ROI) drawing and a time-consuming nonlinear regression on each time activity curve (TAC). In this study, the factor analysis of dynamic structures (FADS) was used to extract the “pure” blood pool TAC and generate a parametric image of MBF (pixel unit: ml/min/g) which can map the myocardial perfusion accurately, Ten dynamic 13N-ammonia dog PET studies (3 baseline, 5 hyperemia, and 2 occlusion) were included. Three factors (TACs) and their corresponding factor images (the tight and left ventricular (RV and LV) blood pools and myocardial activities) were extracted from each study. The LV factors matched well with the plasma TACs, The factor image of myocardium was then converted to parametric image of MBF using a relationship derived from a two-compartment model, The results showed that the MBF obtained from PADS correlated well with MBF by two-compartment model fitting (correlation coefficient (r)t 0.98, slope=0.83) and by microsphere technique (r=0.98, slope=0.95). The FADS generated MIBF images have good image quality and lower noise levels compared to those generated by Patlak graphical analysis (PGA). It is concluded that regional myocardial blood flow can be measured accurately and noninvasively from 13N-ammonia dynamic PET imaging and FADS technique. FADS provides a simple method to map the distribution and magnitude of myocardial perfusion accurately and generate parametric image of MBF without requiring blood sampling and spillover correction
Keywords :
blood flow measurement; cardiology; haemorheology; medical image processing; muscle; positron emission tomography; 13N-ammonia dynamic PET imaging; NH3; Patlak graphical analysis; correlation coefficient; dynamic structures; factor analysis; image quality; medical diagnostic imaging; microsphere technique; myocardial blood flow quantitation; myocardial perfusion; nuclear medicine; parametric image; two-compartment model; Blood flow; Fluid flow measurement; Image analysis; Image generation; Image sampling; Myocardium; Pixel; Plasmas; Positron emission tomography; Time measurement;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
Conference_Location :
Norfolk, VA
Print_ISBN :
0-7803-2544-3
DOI :
10.1109/NSSMIC.1994.474689