Abstract :
To investigate the influence of bypassing treatment on the hemodynamic parameters of aortic dissection and the feasibility of this therapeutic approach in clinical application, idealized three-dimensional geometric models of DeBakey III aortic dissection with a blind lumen and its bypassing treatment were constructed with the software of SolidWorks 2007. Then, numerical simulation was performed utilizing the software of ANSYS 11.0, and the results were analyzed. The velocity of blood flow and the pressure at the entrance area of false lumen and in the false lumen are both less than those before the operation. Bypassing is an effective surgery for the treatment of DeBakey III dissection. It can effectively reduce the pressure of aortic arch and ease the impulsion and stress of blood flow on the pathological dissection. It can also alleviate the propagation, prevent the rupture, and promote the healing of dissection.
Keywords :
biology computing; blood flow measurement; blood vessels; diseases; solid modelling; surgery; 3D computational simulation; 3D geometric models; ANSYS 11.0; DeBakey III aortic dissection; DeBakey III dissection; SolidWorks 2007; aortic arch; blind lumen; blood flow velocity; bypassed aortic dissection; bypassing treatment; false lumen; hemodynamic parameters; pathological dissection; Application software; Blood flow; Computational modeling; Hemodynamics; Numerical simulation; Performance analysis; Software performance; Solid modeling; Stress; Surgery;
Conference_Titel :
Biomedical Engineering and Computer Science (ICBECS), 2010 International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-5315-3
DOI :
10.1109/ICBECS.2010.5462494