Abstract :
A study of electrical transport and detection performances of the bulk semi-insulating InP-based detectors of charged particles and γ rays is presented. The best detectors give a charge collection efficiency over 90% and energy resolution about 3% (FWHM) for 5.48 MeV α-particles and an energy resolution about 7% (FWHM) for 122 keV γ-rays at 220 K. Detection performances versus temperature, contact systems and bias voltage polarity have been discussed
Keywords :
III-V semiconductors; alpha-particle detection; gamma-ray detection; indium compounds; semiconductor counters; α-particle detection; γ-ray detection; 122 keV; 220 K; 5.48 MeV; 90 percent; InP; bulk semi-insulating InP; charge collection efficiency; charged particle detection; electrical transport; energy resolution; particle detector; Energy resolution; Gold; Indium phosphide; Iron; Neutrino sources; Physics; Radiation detectors; Schottky barriers; Temperature; Voltage;