DocumentCode :
2347652
Title :
2B-4 Square-Wave Aperture Weightings for Reception Beam Forming in High Frame Rate Imaging
Author :
Lu, Jian-Yu ; Wang, Jing
Author_Institution :
Dept. of Bioeng., Toledo Univ., OH
fYear :
2006
fDate :
2-6 Oct. 2006
Firstpage :
124
Lastpage :
127
Abstract :
Recently, the high frame rate (HFR) imaging method was extended to include multiple transmission beams such as steered plane waves and limited-diffraction array beams to improve image quality. In addition, limited-diffraction array beam transmissions have been approximated with square-wave aperture weightings so that only one or two transmitters are needed for three-dimensional imaging with a fully populated two-dimensional array transducer, simplifying the transmission subsystem of an imager. In this paper, the square-wave aperture weightings are applied to reception beamforming to simplify the limited-diffraction array beam aperture weightings proposed previously, which allows the production of all spatial frequency components of analog echo signals in realtime over a transducer aperture by direct summation and subtraction of these signals for image reconstructions. This approach reduces the need of some high-speed digital circuits and can also be used as a realtime spatial spectrum analyzer to produce both amplitude and phase of the waves impinging on the surface of a receiver with simple electronics as long as the spatial Nyquist sampling criterion is satisfied. Both in vitro (on an ATS539 phantom) and in vivo (on the hearts and a kidney of volunteers) experiments were performed with a broadband phased array transducer of 2.5 MHz center frequency, 128 elements, and 0.15 mm pitch using a home-made general-purpose HFR imaging system. A one-cycle, 2.5 MHz sine wave pulse was used to excite the transducer with a pulse repetition period of about 187 microseconds. Results show that the quality of images reconstructed with the reception square-wave aperture weightings is very close to that of images reconstructed with the exact limited-diffraction array beam weightings or spatial Fourier transform on echo signals. The images reconstructed have over plusmn45 degree field of view and an image frame rate of about 486/s is achieved for a depth of 120 mm
Keywords :
biomedical ultrasonics; medical image processing; ultrasonic imaging; ultrasonic transducer arrays; 2.5 MHz; 2D transducer array; ATS539 phantom; HFR imaging system; broadband phased array transducer; echo signal; hearts; high frame rate imaging; image quality; image reconstruction; kidney; limited-diffraction array beam weightings; limited-diffraction array beams; medical imaging; multiple transmission beam; reception beam forming; spatial Fourier transform; spatial Nyquist sampling criterion; spatial spectrum analyzer; square-wave aperture weighting; steered plane waves; Apertures; Array signal processing; Digital circuits; Frequency; Image quality; Image reconstruction; Phased arrays; Production; Transducers; Transmitters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2006. IEEE
Conference_Location :
Vancouver, BC
ISSN :
1051-0117
Print_ISBN :
1-4244-0201-8
Electronic_ISBN :
1051-0117
Type :
conf
DOI :
10.1109/ULTSYM.2006.44
Filename :
4151900
Link To Document :