• DocumentCode
    2347658
  • Title

    Using linear time-invariant system theory to estimate kinetic parameters directly from projection measurements

  • Author

    Zeng, Gengsheng L. ; Gullberg, Grant T. ; Huesman, Ronald H.

  • Author_Institution
    Dept. of Radiol., Utah Univ., Salt Lake City, UT, USA
  • Volume
    4
  • fYear
    1994
  • fDate
    30 Oct-5 Nov 1994
  • Firstpage
    1739
  • Abstract
    In a dynamic SPECT (single photon emission computed tomography) study, if an image is reconstructed for each detector rotation, the image will contain errors as the data for each projection angle are acquired at different times in the dynamic study. These errors will affect the kinetic parameter estimation. We hypothesize that more accurate estimates can be obtained if the parameters are estimated directly from the projections than from the reconstructions. It is more difficult to estimate the parameters from the projections than from the reconstructions. In the reconstructed images, all the regions are well separated, while in projections the regions are mixed. Estimation from the projections requires all projections of the kinetic models for each region. This results in a relatively complicated objective function, which is usually not well behaved and has many local minima due to the non-linear exponential terms. We propose a technique to estimate the exponential parameters separately using a linear model, which has a closed-form solution for the one parameter case and has a unique solution via the singular value decomposition (SVD) for the multiple parameter case. The other multiplicative parameters also have a linear model and are estimated once the exponential parameters have been fixed. The objective function with fixed exponential parameters is quadratic and well-behaved. No local minima are observed in computer simulations, which enabled us to obtain accurate estimation. Our computer simulations demonstrate that estimation directly from the projections are more accurate than the estimation from the reconstructed images
  • Keywords
    image reconstruction; medical image processing; parameter estimation; single photon emission computed tomography; singular value decomposition; closed-form solution; computer simulations; detector rotation; dynamic SPECT; errors; exponential parameters; image reconstruction; kinetic parameter estimation; kinetic parameters; linear model; linear time-invariant system theory; local minima; multiple parameter case; multiplicative parameters; nonlinear exponential terms; objective function; projection angle; projection measurements; projections; quadratic objective function; single photon emission computed tomography; singular value decomposition; Cities and towns; Closed-form solution; Computer simulation; Estimation theory; Image reconstruction; Kinetic theory; Laboratories; Parameter estimation; Positron emission tomography; Radiology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
  • Conference_Location
    Norfolk, VA
  • Print_ISBN
    0-7803-2544-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1994.474728
  • Filename
    474728