    NECR analysis of 3D brain PET scanner designs

  • Author

    Stearns, Charles W. ; Cherry, Simon R. ; Thompson, Christopher J.

  • Author_Institution
    GE Med. Syst., Milwaukee, WI, USA
  • Volume
    4
  • fYear
    1994
  • fDate
    30 Oct-5 Nov 1994
  • Firstpage
    1657
  • Abstract
    A dedicated 3D brain PET scanner has several advantages, most notably increased sensitivity, over a whole body scanner for neurological studies. However brain scanners have higher scatter fractions, random count-rates and deadtime for the same activity concentration. We have used noise effective count-rate (NECR) analysis to compare brain scanners of 53, 60, and 66 cm diameter with the GE ADVANCE whole body scanner (93 cm diameter). Monte Carlo simulations of a brain-sized phantom (16 cm diameter, 13 cm length) in the ADVANCE geometry were used to develop a model for NECR performance, which was reconciled to results from a decay series measurement. The model was then used to predict the performance of the brain scanner designs. The brain scanners have noise effective sensitivities (the slope of the NECR curve at zero activity) as much as 40% higher than ADVANCE. However, their NECR advantage diminishes quickly as the activity concentration increases; the brain scanners´ NECR equals ADVANCE at ~0.3 μCi/cc, and ADVANCE has superior NECR performance at higher activity levels. An imaging center concentrating on only very low activity imaging tasks would find the efficiency advantage of a smaller detector diameter valuable, while a center performing higher activity studies such as bolus water injections or 5 mCi FDG injections might prefer the count rate performance of a whole body scanner
  • Keywords
    Monte Carlo methods; biomedical equipment; brain; gamma-ray detection; photon transport theory; positron emission tomography; radioactivity measurement; 13 cm; 16 cm; 3D brain PET scanner designs; 53 cm; 5E-3 Ci; 60 cm; 66 cm; 93 cm; GE ADVANCE whole body scanner; Monte Carlo simulations; NECR analysis; activity concentration; bolus water injections; brain-sized phantom; count rate performance; deadtime; decay series measurement; higher scatter fractions; imaging center; increased sensitivity; noise effective count-rate analysis; noise effective sensitivities; random count-rates; Brain modeling; Detectors; Geometry; Imaging phantoms; Length measurement; Positron emission tomography; Predictive models; Scattering; Solid modeling; Whole-body PET;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
  • Conference_Location
    Norfolk, VA
  • Print_ISBN
    0-7803-2544-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1994.474745
  • Filename
    474745