Title :
Operating experience and cost savings with FLSA´s QCX/OnStream analyzer installed at St Marys Cement Co., Bowmanville, Ontario, Canada
Author :
Collins, Robert E. ; Blue, Robert J. ; Mound, Michael C.
Author_Institution :
St. Marys Cement Co., Bowmanville, Ont., Canada
Abstract :
The Bowmanville plant of St Marys Cement is located about 60 km east of Toronto, Canada, on the north shore of lake Ontario. This plant has been in operation since 1968, and was expanded most recently in 1991. Here, the authors describe how, at that time, a 5000 mtpd dry process preheater, precalciner kiln was commissioned to replace the two existing 1000 mtpd wet kilns. The major equipment installations included a 4000 t/h Atox mill for raw grinding, a 42,000 tonne controlled flow silo for kiln feed homogenization, and a separate line calciner (SLC) kiln system complete with grate cooler. The control system included QCX (Quality Control by Computer and X-ray), FuzzyLogic, and CemScanner
Keywords :
cement industry; grinding; maintenance engineering; materials handling; process control; project engineering; Atox mill; Canada; CemScanner; FuzzyLogic; QCX; cement plant; control system; controlled flow silo; dry process preheater; equipment installations; kiln feed homogenization; modernisation; operating experience; precalciner kiln; projects; raw grinding; separate line calciner; Automation; Cement industry; Chemistry; Control systems; Costs; Kilns; Lakes; Milling machines; Silicon compounds; Temperature control;
Conference_Titel :
Cement Industry Technical Conference, 1995. XXXVII Conference Record., 1995 IEEE
Conference_Location :
San Juan
Print_ISBN :
0-7803-2456-0
DOI :
10.1109/CITCON.1995.514247