DocumentCode
2351970
Title
A new directional relay based on the measurement of fault generated current transients
Author
Bo, Z.Q. ; Johns, A.T. ; Aggarwal, R.K.
Author_Institution
Bath Univ., UK
fYear
1997
fDate
25-27 Mar 1997
Firstpage
227
Lastpage
230
Abstract
This paper presents a new principle in directional relaying in which the fault direction is determined based on a comparison of the spectral energy of the fault generated high frequency current transient components. In this scheme, a current transient detection unit, which is interfaced to the CTs on each of the output lines connecting the busbar, is employed to capture the fault generated transient current signals. The transient signal captured from each line is first integrated (based on a small window of information) to obtain its spectral energy; the level of the energy entering the busbar is then compared with that leaving it, to ascertain the direction of the fault. It is shown that the detector is also able to make correct discrimination when a fault occurs on the busbar. Simulation studies were carried out using the EMTP software. The faulted responses were examined with respect to various system and fault conditions
Keywords
power system protection; EMTP software; busbar; current transient detection unit; current transients measurement; directional relay; fault direction determination; fault generated current transients; high frequency current transient; simulation; spectral energy;
fLanguage
English
Publisher
iet
Conference_Titel
Developments in Power System Protection, Sixth International Conference on (Conf. Publ. No. 434)
Conference_Location
Nottingham
ISSN
0537-9989
Print_ISBN
0-85296-672-5
Type
conf
DOI
10.1049/cp:19970069
Filename
608187
Link To Document