Title :
4K-2 3D Acoustic Radiation Force Impulse (ARFI) Imaging using a 2D Matrix Array: Feasibility Study
Author :
Fronheiser, Matthew P. ; Dahl, Jeremy J. ; Pinton, Gianmarco F. ; Chao, Zubair ; Smith, Stephen W.
Author_Institution :
Dept. of Biomed. Eng., Duke Univ., Durham, NC
Abstract :
Acoustic radiation force impulse (ARFI) imaging has been reported as a successful method of measuring mechanical properties of tissue. Current methods use linear arrays to obtain a 2D image of tissue displacement. In this study, we have modified our real-time 3D ultrasound system (Volumetrics Medical Imaging, Durham, NC) to acquire volumetric ARFI data and create 3D displacement images. To ensure that the pulse to pulse correlation values from a 2.5-MHz matrix array transducer with 440 transmit and 256 receive channels were sufficient for ARFI processing, we transmitted a series of 2-cycle pulses into a homogeneous 4 kPa tissue-mimicking phantom (CIRS, Norfolk, VA) and collected corresponding 16:1 parallel received RF lines spaced 1.2deg apart. We found pulse to pulse normalized cross-correlation values were greater than 0.995 for scan depths of 3.5 cm. Our 3D ARFI pulse sequence consists of 3 2-cycle reference pulses followed by a set of 3 256-cycle pushing pulses. A series of 42 2-cycle tracking pulses are then used to monitor the displacement of the sample volume. Displacements between the reference and tracking RF data are estimated with ultrasonic cross-correlation methods. When acquiring a single scan line in a tissue mimicking phantom with a Young´s modulus of 4 kPa, we measured maximum displacements of approximately 3 mum near the focus. 3D ARFI images were produced at depths of 0.5-3.5 cm using 9 transmit lines, which produced 144 receive lines to form a 12 line by 12 line 3D pyramid of 13.2deg yielding B-scan and C-scan planes of displacement data. System modifications are ongoing to the 3D Doppler processing algorithm (1D autocorrelation) to permit 3D ARFI processing to occur in realtime
Keywords :
biological tissues; biomedical ultrasonics; phantoms; ultrasonic imaging; ultrasonic measurement; ultrasonic transducers; 0.5 to 3.5 cm; 1D autocorrelation; 2.5 MHz; 2D matrix array; 3D ARFI imaging; 3D Doppler processing algorithm; 3D displacement images; 4 kPa; B-scan; C-scan; Young´s modulus; acoustic radiation force impulse; biological tissue; linear arrays; matrix array transducer; mechanical properties; real-time 3D ultrasound system; tissue displacement; tissue mimicking phantom; ultrasonic cross-correlation method; Acoustic arrays; Acoustic imaging; Acoustic measurements; Biomedical acoustics; Force measurement; Imaging phantoms; Mechanical variables measurement; Radio frequency; Ultrasonic imaging; Ultrasonic variables measurement;
Conference_Titel :
Ultrasonics Symposium, 2006. IEEE
Conference_Location :
Vancouver, BC
Print_ISBN :
1-4244-0201-8
Electronic_ISBN :
1051-0117
DOI :
10.1109/ULTSYM.2006.296