DocumentCode
2352505
Title
Identification of Dead-Time Influence on The Output Voltage of the Inverter Controlled by Non-Linear Controllers
Author
Sikorski, Andrzej ; Korzeniewski, Marek ; Ruszczyk, Adam
Author_Institution
Bialystok Tech. Univ., Bialystok
fYear
2007
fDate
9-12 Sept. 2007
Firstpage
1896
Lastpage
1901
Abstract
The influence of the dead-time on a inverter VSI output voltage vector controlled by SVM where the switching sequence is defined, is well known. Towards of the inverters used nonlinear controllers, where the sequence of the succeeding voltage vectors maybe of one´s choice, the dead-time influence evaluation is different. The method evaluation of dead-time influence on the output voltage of the inverter controlled by nonlinear controllers is presented in the article. The laboratory test results confirm correctness of this analysis and elaborated correction algorithm.
Keywords
invertors; machine control; nonlinear control systems; voltage control; dead-time influence; direct torque; induction motor drives; inverter VSI output voltage vector; nonlinear control; switching sequence; voltage error correction; Control systems; Error correction; Hardware; Nonlinear control systems; Pulse width modulation; Pulse width modulation inverters; Support vector machines; Switches; Torque control; Voltage control; Non-linear control; direct torque and flux control; induction motor drives; voltage error correction;
fLanguage
English
Publisher
ieee
Conference_Titel
EUROCON, 2007. The International Conference on "Computer as a Tool"
Conference_Location
Warsaw
Print_ISBN
978-1-4244-0813-9
Electronic_ISBN
978-1-4244-0813-9
Type
conf
DOI
10.1109/EURCON.2007.4400559
Filename
4400559
Link To Document