Abstract :
Two hydro generators were chosen to renew the stator winding. The motivation of this investment was an expertise about the condition of the generators. Beside technical diagnosis the operational dates and maintenance history was taken into account as well as the age of these generators. The stator windings were replaced with an insulation system that had the benefit of a 10 % power increase. The aged generator bars were tested in laboratory with the focus on the residual lifetime. Voltage endurance tests and optical investigations were done and statistically analysed. The result of these investigations confirmed the decision of the renewal of the stator winding
Keywords :
ageing; bars; hydroelectric generators; insulation testing; investment; machine insulation; machine testing; maintenance engineering; statistical analysis; stators; ageing; bars; hydro generator lifetime; insulation system; investment; maintenance history; statistical analysis; stator winding renewal; technical diagnosis; voltage endurance test; Bars; Capacitance measurement; Dielectric measurements; Insulation testing; Life testing; Optical pumping; Partial discharge measurement; Partial discharges; Stator windings; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation, 2006. Conference Record of the 2006 IEEE International Symposium on
Conference_Location :
Toronto, Ont.
ISSN :
1089-084X
Print_ISBN :
1-4244-0333-2
Type :
conf
DOI :
10.1109/ELINSL.2006.1665268
Filename :
1665268
Link To Document :
بازگشت