• DocumentCode
    2352822
  • Title

    PD measurements during the degradation of twisted pair enameled wires subjected to repetitive voltage impulses

  • Author

    Guastavino, F. ; Dardano, A. ; Ratto, A. ; Torello, E.

  • Author_Institution
    Electr. Eng. Dept., Univ. degli Studi di Genova
  • fYear
    2006
  • fDate
    11-14 June 2006
  • Firstpage
    147
  • Lastpage
    150
  • Abstract
    The present work concerns the partial discharge (PD) activity in simple insulating system (twisted pairs) when switching voltage waveforms are applied. A special low frequency PD coupling system allowed to determine two quantities indicating the stress actually connected with the PD activity. Such parameters have been considered to determine life prediction models
  • Keywords
    enamels; insulated wires; insulation testing; life testing; partial discharge measurement; PD measurement; coupling system; enamel wire degradation; insulating system; life prediction model; partial discharge; twisted pair testing; voltage impulse; Aging; Cable insulation; Degradation; Dielectrics and electrical insulation; Partial discharges; Performance evaluation; Pulse measurements; Pulse width modulation; Voltage; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 2006. Conference Record of the 2006 IEEE International Symposium on
  • Conference_Location
    Toronto, Ont.
  • ISSN
    1089-084X
  • Print_ISBN
    1-4244-0333-2
  • Type

    conf

  • DOI
    10.1109/ELINSL.2006.1665278
  • Filename
    1665278