DocumentCode
2352822
Title
PD measurements during the degradation of twisted pair enameled wires subjected to repetitive voltage impulses
Author
Guastavino, F. ; Dardano, A. ; Ratto, A. ; Torello, E.
Author_Institution
Electr. Eng. Dept., Univ. degli Studi di Genova
fYear
2006
fDate
11-14 June 2006
Firstpage
147
Lastpage
150
Abstract
The present work concerns the partial discharge (PD) activity in simple insulating system (twisted pairs) when switching voltage waveforms are applied. A special low frequency PD coupling system allowed to determine two quantities indicating the stress actually connected with the PD activity. Such parameters have been considered to determine life prediction models
Keywords
enamels; insulated wires; insulation testing; life testing; partial discharge measurement; PD measurement; coupling system; enamel wire degradation; insulating system; life prediction model; partial discharge; twisted pair testing; voltage impulse; Aging; Cable insulation; Degradation; Dielectrics and electrical insulation; Partial discharges; Performance evaluation; Pulse measurements; Pulse width modulation; Voltage; Wires;