  • Abstract
    This paper compares the dielectric, impregnation, and handling characteristics of calcined and uncalcined (integrated) mica tapes designed for a vacuum pressure impregnation (VPI) insulation system. The evaluation techniques used to rank the tapes are discussed, including diagnostic tests, accelerated ageing tests, compatibility tests, and manufacturability trials. The potential correlation between dielectric loss and accelerated ageing life of the VPI-treated mica tapes is also investigated. The qualification of the mica tape with the best overall performance for a VPI insulation system is explained, and the process for implementation of the tape in a manufacturing environment is described
  • Keywords
    dielectric losses; impregnated insulation; insulation testing; life testing; machine insulation; machine testing; manufacturing processes; mica; stators; vacuum insulation; AC stator winding insulation; VPI mica tape; accelerated ageing test; compatibility test; diagnostic test; dielectric characteristics; dielectric loss; manufacturing process; vacuum pressure impregnation insulation; Accelerated aging; Dielectric losses; Dielectrics and electrical insulation; Life estimation; Manufacturing; Qualifications; Stator windings; Testing; Vacuum systems; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 2006. Conference Record of the 2006 IEEE International Symposium on
  • Conference_Location
    Toronto, Ont.
  • ISSN
    1089-084X
  • Print_ISBN
    1-4244-0333-2
  • Type

    conf

  • DOI
    10.1109/ELINSL.2006.1665327
  • Filename
    1665327