GPS satellite synchronized test systems recreate fault conditions to troubleshoot protective relay schemes
Author
Lillian, Marlène ; Thompson, Stanley I.
Author_Institution
El Paso Electr. Co., TX, USA
fYear
1997
fDate
25-27 Mar 1997
Firstpage
346
Lastpage
350
Abstract
El Paso Electric had been experiencing misoperations on a segregated phase comparison (SPCU-1A) relay scheme at the Caliente substation (a 345 kV and 115 kV switching station). For faults occurring on the AMRAD to Caliente transmission line, the SPCU schemes for both the AMRAD-Caliente and Newman-Caliente 345 kV transmission lines operated, leaving the east side of El Paso without a 345 kV source. Fault records were taken at the three sites (AMRAD, Newman and Caliente). Composite files were created from the AMRAD and Caliente, and Newman and Caliente waveforms. Hathaway Composite software was used to time-scew, or “line up”, the fault inception at the different substations for each file. These files were then converted to IEEE COMTRADE file format using Hathaway EX-IMPORT software. AVO Multi-Amp PulseMaster software was then used to create test files by adding prefault data and converting waveform magnitudes to secondary values. Portable Global Positioning System (GPS) satellite receivers were used to synchronously begin the automated end-to-end testing of the relay schemes. The synchronous test system was used to provide repeatability in testing and verifying both the AMRAD and Newman protection schemes. Changes were made to peripheral devices (such as current transformers) as well as to jumper locations within the relays. The test files were used to verify the response of the relay schemes to these changes
Keywords
power system protection; 115 kV; 345 kV; AMRAD to Caliente transmission line; AVO Multi-Amp PulseMaster software; Caliente substation; El Paso Electric; GPS satellite synchronized test systems; Global Positioning System; Hathaway Composite software; Hathaway EX-IMPORT software; IEEE COMTRADE file format; Newman-Caliente transmission line; SPCU-1A relay scheme; automated end-to-end testing; composite files; fault conditions recreation; fault inception; jumper locations; portable GPS satellite receivers; prefault data; protective relay schemes troubleshooting; segregated phase comparison relay; synchronous test system; test files;
fLanguage
English
Publisher
iet
Conference_Titel
Developments in Power System Protection, Sixth International Conference on (Conf. Publ. No. 434)
Conference_Location
Nottingham
ISSN
0537-9989
Print_ISBN
0-85296-672-5
Type
conf
DOI
10.1049/cp:19970096
Filename
608221
Link To Document