• DocumentCode
    2356365
  • Title

    Air flow estimation in the presence of motion artifacts

  • Author

    Luo, Shen ; Tompkins, Willis J. ; Webster, John G.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Wisconsin Univ., Madison, WI, USA
  • fYear
    1994
  • fDate
    1994
  • Firstpage
    966
  • Abstract
    Provides a method to estimate occurrence of air flow even when large-amplitude motion artifacts occur. Simultaneously using several body-motion sensors with different measuring principles plus optimal placement for acquiring ventilation signals provides a high correlation of the signal components and a low correlation of the motion artifact components. We developed spatial averaging and multidimensional detection algorithms for ventilation monitoring to identify whether the signals acquired were from ventilatory efforts without air flow in the presence of body motion or from normal body motion with air flow. We sampled data from 14 adult male subjects according to a specific protocol. This study shows that signal crosscorrelation using a three-sensor system (one-impedance plus two-inductance sensors) can detect normal breathing, central apnea, the paroxysmal breathing caused by simulating obstructive apnea, and can estimate with a high probability whether air flow occurs during movement
  • Keywords
    biomedical measurement; correlation methods; electric impedance measurement; flow measurement; inductance measurement; medical signal processing; pneumodynamics; adult male subjects; air flow estimation; body-motion sensors; central apnea; correlation; impedance sensor; inductance sensors; large-amplitude motion artifacts; measuring principles; motion artifact components; multidimensional detection algorithms; normal breathing; obstructive apnea; optimal placement; paroxysmal breathing; signal components; signal crosscorrelation; spatial averaging; specific protocol; three-sensor system; ventilation monitoring; ventilation signals; Area measurement; Fluid flow measurement; Impedance measurement; Motion estimation; Motion measurement; Plethysmography; Protocols; Sensor systems; Thermal variables measurement; Ventilation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1994. Engineering Advances: New Opportunities for Biomedical Engineers. Proceedings of the 16th Annual International Conference of the IEEE
  • Conference_Location
    Baltimore, MD
  • Print_ISBN
    0-7803-2050-6
  • Type

    conf

  • DOI
    10.1109/IEMBS.1994.415236
  • Filename
    415236