DocumentCode :
235837
Title :
Fast and easy sample preparation with reduced curtaining artifacts using a P-FIB
Author :
Moreau, Sandrine ; Bouchu, D. ; Audoit, G.
Author_Institution :
Univ. Grenoble Alpes, Grenoble, France
fYear :
2014
fDate :
June 30 2014-July 4 2014
Firstpage :
231
Lastpage :
235
Abstract :
The present methodology proposes to reduce curtaining artifacts using a plasma-FIB when milling relatively deep trenches. Finally, the methodology is very fast (<;1 h), simple to set up and can be automated. Its purpose consists in eliminating or reducing the origin of curtaining artifacts by judicious milling. This methodology can advantageously replace the rocking method presented in the literature.