Abstract :
The 50 μm microvias of an defective embedded device were inspected non-destructively by both highly resolving microfocus computed tomography and improved digital X-ray imaging. Voids were found within the via fills and open interconnections between vias and pads were detected by the X-ray inspections. These defects could be verified and visualised in three dimensions by nanofocus CT.
Keywords :
computerised tomography; electronics packaging; inspection; nondestructive testing; digital X-ray imaging; digital X-ray inspection; microfocus computed tomography; miniaturised interconnection; nanofocus CT; size 50 micron;