DocumentCode :
235957
Title :
Sampling current ratio bridge for calibration of current transducers up to 10 kA with 5 ppm uncertainty
Author :
van den Brom, Helko E. ; Rietveld, Gert ; So, Eddy
Author_Institution :
VSL Dutch Metrol. Inst., Delft, Netherlands
fYear :
2014
fDate :
24-29 Aug. 2014
Firstpage :
8
Lastpage :
9
Abstract :
A sampling current ratio bridge has been developed, tested and validated for the accurate complex ratio measurement of AC current transducers for primary currents up to 10 kA with expanded uncertainties of 5 · 10-6 in magnitude and 5 μrad in phase (k = 2). A unique property of the system is the use of digitizers for sampling of the secondary current signals and step-down transformers with a large number of current ratios. This allows for the accurate calibration of a large variety of different current transformers and other types of current transducers.
Keywords :
bridge circuits; current transformers; electric current measurement; measurement uncertainty; signal sampling; transducers; AC current transducer calibration; calibration; complex ratio measurement; current 10 kA; current transformer; measurement uncertainty; sampling current ratio bridge; secondary current signal sampling; step down transformer; Bridge circuits; Calibration; Current measurement; Current transformers; Transducers; Uncertainty; Windings; Current transducers; current measurement; current ratio; current transformers; sampling; uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location :
Rio de Janeiro
ISSN :
0589-1485
Print_ISBN :
978-1-4799-5205-2
Type :
conf
DOI :
10.1109/CPEM.2014.6898232
Filename :
6898232
Link To Document :
بازگشت