DocumentCode
235979
Title
A new method to compare two thermal current converters at common ground at frequency up to 200 kHz
Author
Xianlin Pan ; Jiangtao Zhang ; Yang Gu ; Wenfang Liu ; Hongtao Huang ; Deshi Zhang
Author_Institution
Nat. Inst. of Metrol., Beijing, China
fYear
2014
fDate
24-29 Aug. 2014
Firstpage
46
Lastpage
47
Abstract
A new method to measure two thermal current converters at common ground by means of binary inductive current divider has been employed and compare with traditional voltage mode. The measurement results of two methods has been given at frequencies up to 200 kHz, and shown well agreement in frequency response against 1 kHz.
Keywords
convertors; electric current measurement; frequency response; binary inductive current divider; common ground; frequency response; thermal current converters; Current measurement; Electrical resistance measurement; Frequency conversion; Frequency measurement; Frequency response; Metrology; Voltage measurement; Thermal current converter; ac-dc transfer; binary inductive current divider; common ground; electromagnetic metrology;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location
Rio de Janeiro
ISSN
0589-1485
Print_ISBN
978-1-4799-5205-2
Type
conf
DOI
10.1109/CPEM.2014.6898251
Filename
6898251
Link To Document