• DocumentCode
    2360094
  • Title

    Efficiency comparison of voltage source and current source drive system for medium voltage applications

  • Author

    Suh, Yongsug ; Steinke, Juergen ; Steimer, Peter

  • Author_Institution
    ABB Switzerland Ltd., Turgi
  • fYear
    2005
  • fDate
    11-14 Sept. 2005
  • Abstract
    This paper calculates and compares the efficiency and loss distribution in three most popular state-of-the-art types of medium voltage drive systems; current source drive with active front-end rectifier, current source drive with 18-pulse thyristor rectifier, and three-level voltage source drive with 12-pulse/24-pulse diode rectifier. Based on the proposed simple and accurate method of calculating switching losses, snubber and filter losses, three-level voltage source drive system has been found to produce the highest efficiency of 98.77% under the rated load of 1.6 MW
  • Keywords
    diodes; electric drives; power filters; rectifying circuits; snubbers; switching convertors; thyristor applications; 1.6 MW; 18-pulse thyristor rectifier; active front-end rectifier; current source drive; current source drive system; diode rectifier; filter losses; loss distribution; medium voltage applications; snubbers; switching losses; three-level voltage source drive; three-level voltage source drive system; voltage drive systems; voltage source; Drives; Filters; Inverters; Loss measurement; Medium voltage; Power system reliability; Rectifiers; Switching converters; Switching loss; Thyristors; AC machine; Current source inverter; Efficiency; Multilevel converters; Voltage source inverters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications, 2005 European Conference on
  • Conference_Location
    Dresden
  • Print_ISBN
    90-75815-09-3
  • Type

    conf

  • DOI
    10.1109/EPE.2005.219486
  • Filename
    1665676