DocumentCode
236010
Title
High-accuracy measurement of power quality parameters using asynchronous sampling technique
Author
Lapuh, Rado ; Voljc, Bostjan ; Kokalj, Miha ; Pinter, Borut ; Svetik, Zoran ; Lindic, Matjaz
Author_Institution
Slovenian Inst. of Quality & Metrol., Ljubljana, Slovenia
fYear
2014
fDate
24-29 Aug. 2014
Firstpage
76
Lastpage
77
Abstract
The paper describes the measurement procedure for calibration of power quality parameters. Procedure uses the asynchronous sampling technique with multi harmonic sine fit algorithm to separately determine harmonics, interharmonics, fluctuating harmonics and flickers. It gives small enough uncertainties to cover calibrations of all commercially available power quality sources and meters.
Keywords
calibration; power measurement; power meters; power supply quality; power system harmonics; sampling methods; asynchronous sampling technique; calibration; flicker; fluctuating harmonics; interharmonics; multiharmonic sine fit algorithm; power meter; power quality parameter measurement; Calibration; Frequency measurement; Frequency modulation; Harmonic analysis; Measurement uncertainty; Power quality; Uncertainty; Power quality parameters; asynchronous sampling; flickers; harmonics; measurement system; measurement technique; uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location
Rio de Janeiro
ISSN
0589-1485
Print_ISBN
978-1-4799-5205-2
Type
conf
DOI
10.1109/CPEM.2014.6898266
Filename
6898266
Link To Document