• DocumentCode
    236010
  • Title

    High-accuracy measurement of power quality parameters using asynchronous sampling technique

  • Author

    Lapuh, Rado ; Voljc, Bostjan ; Kokalj, Miha ; Pinter, Borut ; Svetik, Zoran ; Lindic, Matjaz

  • Author_Institution
    Slovenian Inst. of Quality & Metrol., Ljubljana, Slovenia
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    76
  • Lastpage
    77
  • Abstract
    The paper describes the measurement procedure for calibration of power quality parameters. Procedure uses the asynchronous sampling technique with multi harmonic sine fit algorithm to separately determine harmonics, interharmonics, fluctuating harmonics and flickers. It gives small enough uncertainties to cover calibrations of all commercially available power quality sources and meters.
  • Keywords
    calibration; power measurement; power meters; power supply quality; power system harmonics; sampling methods; asynchronous sampling technique; calibration; flicker; fluctuating harmonics; interharmonics; multiharmonic sine fit algorithm; power meter; power quality parameter measurement; Calibration; Frequency measurement; Frequency modulation; Harmonic analysis; Measurement uncertainty; Power quality; Uncertainty; Power quality parameters; asynchronous sampling; flickers; harmonics; measurement system; measurement technique; uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898266
  • Filename
    6898266