Abstract :
The paper describes the measurement procedure for calibration of power quality parameters. Procedure uses the asynchronous sampling technique with multi harmonic sine fit algorithm to separately determine harmonics, interharmonics, fluctuating harmonics and flickers. It gives small enough uncertainties to cover calibrations of all commercially available power quality sources and meters.
Keywords :
calibration; power measurement; power meters; power supply quality; power system harmonics; sampling methods; asynchronous sampling technique; calibration; flicker; fluctuating harmonics; interharmonics; multiharmonic sine fit algorithm; power meter; power quality parameter measurement; Calibration; Frequency measurement; Frequency modulation; Harmonic analysis; Measurement uncertainty; Power quality; Uncertainty; Power quality parameters; asynchronous sampling; flickers; harmonics; measurement system; measurement technique; uncertainty;