DocumentCode
2360536
Title
Fast 3-D Total Radiated Sensitivity measurement technique for mobile terminals
Author
Pannetrat, Stéphane ; Leray, Christian ; Derat, Benoît
Author_Institution
Mobile Phones R&D Dept., SAGEM Commun., Cergy St. Christophe
fYear
2006
fDate
6-10 Nov. 2006
Firstpage
1
Lastpage
5
Abstract
3-D pattern measurement in anechoic rooms is now widely used for evaluating mobile phones radiated performances. The preferred parameter in the reception mode is the total radiated sensitivity (TRS). The TRS is in fact the main topic of this paper, which proposes approaches to speed up the evaluation of this quantity in anechoic rooms. Based on the estimation of the point sensitivity from specific network parameters, the fastest of the proposed methods allows to assess the TRS in about 30 minutes for 2G terminals, and 50 minutes for 3G. First experimental results show an encouraging maximal deviation of 0.6 dB between the TRS evaluated with the fast 3-D approach and the standard technique.
Keywords
anechoic chambers (electromagnetic); mobile communication; mobile handsets; parameter estimation; 3-D total radiated sensitivity measurement; anechoic rooms; mobile phones; parameter estimation; Antenna measurements; Bit error rate; Frequency; Loss measurement; Measurement standards; Measurement techniques; Mobile handsets; Performance evaluation; Power measurement; Specific absorption rate;
fLanguage
English
Publisher
ieee
Conference_Titel
Antennas and Propagation, 2006. EuCAP 2006. First European Conference on
Conference_Location
Nice
Print_ISBN
978-92-9092-937-6
Type
conf
DOI
10.1109/EUCAP.2006.4584835
Filename
4584835
Link To Document