DocumentCode :
236067
Title :
Using inductive voltage divider to measure the millivolt ac voltage at frequencies up to 100 kHz
Author :
Xianlin Pan ; Wenfang Liu ; Zhiguo Tu ; Jiangtao Zhang ; Deshi Zhang
Author_Institution :
Nat. Inst. of Metrol., Beijing, China
fYear :
2014
fDate :
24-29 Aug. 2014
Firstpage :
134
Lastpage :
135
Abstract :
A method to measure the millivolt ac voltage has been described. The method is based on use of the binary inductive voltage divider and 2n:1IVDs. The measurement setup for the calibration of the 2n:1IVD has been proposed and the results have also been given at frequencies up to 100 kHz.
Keywords :
calibration; voltage dividers; voltage measurement; 2n:1IVD; binary inductive voltage divider; calibration; frequency 100 kHz; millivolt AC voltage measurement; Calibration; Frequency conversion; Frequency measurement; Measurement uncertainty; Metrology; Standards; Voltage measurement; Millivolt ac voltage; binary inductive voltage divider; ratio errors; self-calibrated; uncertainties;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location :
Rio de Janeiro
ISSN :
0589-1485
Print_ISBN :
978-1-4799-5205-2
Type :
conf
DOI :
10.1109/CPEM.2014.6898295
Filename :
6898295
Link To Document :
بازگشت