• DocumentCode
    236105
  • Title

    Realization of low power measurement system in the range of −60 dBm – −120 dBm up to 26.5 GHz

  • Author

    Celep, Murat ; Hayirli, Cem ; Yaran, Senel ; Sakarya, Handan ; Dolma, Arif

  • Author_Institution
    TUBITAK Ulusal Metroloji Enstitusu, Gebze-Kocaeli, Turkey
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    172
  • Lastpage
    173
  • Abstract
    This paper describes measurement system established for microwave low power measurement at TüBITAK UME. System was carried through the superheterodyne type receiver. The system was realized between 100 MHz to 26.5 GHz frequency range. Also error model of the system was analyzed. The output power of a signal source was measured between -60 dBm to -120 dBm. The expanded uncertainty (k=2) of the measured power is between 0.19 dB to 3.04 dB in all frequency range.
  • Keywords
    UHF measurement; measurement errors; measurement uncertainty; microwave measurement; power measurement; superheterodyne receivers; TÜBİTAK UME; frequency 100 MHz to 26.5 GHz; gain 0.19 dB to 3.04 dB; measurement uncertainty; microwave low power measurement system; signal source measurement; superheterodyne type receiver; Attenuators; Frequency measurement; Microwave measurement; Power amplifiers; Power generation; Power measurement; Radio frequency; Low power; measurement; microwave; superheterodyne receiver; traceability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898314
  • Filename
    6898314