DocumentCode
2364294
Title
Polyimide passivation approaches on double-mesa thyristors
Author
Matsumoto, Yasuhiro ; Saucedo, Emmanuel
Author_Institution
Departamento de Ingenieria Electrica, CINVESTAV del IPN, Zacatenco, Mexico
fYear
2005
fDate
7-9 Sept. 2005
Firstpage
223
Lastpage
226
Abstract
Polyimide layers have been applied by a simple blade squeeze technique on double-mesa high voltage thyristor devices for its electrical passivation. Reverse and forward electrical blocking characteristics were measured as a function of polyimide application and curing processing conditions. During high temperature reverse bias reliability test, the thyristors showed appreciable leak-current increment, but after three day thermal process, the devices showed lower leakage currents than that devices fabricated by conventional glassivation technique.
Keywords
curing; passivation; reliability; thyristors; blade squeeze technique; curing processing; double-mesa thyristors; electrical blocking characteristics; electrical passivation; glassivation; leak-current increment; polyimide layers; polyimide passivation; reverse bias reliability test; Blades; Curing; Electric variables measurement; Leakage current; Passivation; Polyimides; Temperature; Testing; Thyristors; Voltage; Passivation; Polyimide; Thyristor;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical and Electronics Engineering, 2005 2nd International Conference on
Print_ISBN
0-7803-9230-2
Type
conf
DOI
10.1109/ICEEE.2005.1529613
Filename
1529613
Link To Document