• DocumentCode
    236436
  • Title

    Interpolating AC-DC transfer differences for an AC-DC voltage transfer standard

  • Author

    Jing, Tai ; Sim, Jae-Yoon

  • Author_Institution
    Nat. Metrol. Centre, A*STAR, Singapore, Singapore
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    508
  • Lastpage
    509
  • Abstract
    The AC-DC difference of an AC-DC transfer standard varies with its input voltage and ac frequencies. Its calibration may not necessarily cover all the voltage-frequency points for their possible uses in practice. This results in situations when there is no reference value to use such a transfer standard for calibrations at some voltage-frequency points. This paper analyses the principle structure of a transfer standard, shows the possibility of interpolating points based on calibrated ones, and presents the interpolation results performed in the National Metrology Centre (NMC).
  • Keywords
    calibration; electric current measurement; interpolation; transfer standards; voltage measurement; AC-DC voltage transfer standard; NMC; National Metrology Centre; calibration; interpolating AC-DC transfer difference; voltage-frequency point; Calibration; Interpolation; Linear regression; Metrology; Resistors; Standards; Uncertainty; AC-DC voltage transfer; calibration; linearity; measurement techniques; measurement uncertainty; regression analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898482
  • Filename
    6898482