DocumentCode :
236481
Title :
Calibration of measuring network of leakage current tester
Author :
Xuefeng Ma ; Guoying Tian ; Ruiji Cao ; Wenqiang Li ; Qin Zhang ; Xinyan Wang
Author_Institution :
Shandong Provincial Key Lab. of Metrol. & Meas., Shandong Inst. of Metrol., Jinan, China
fYear :
2014
fDate :
24-29 Aug. 2014
Firstpage :
554
Lastpage :
555
Abstract :
In this paper, a novel method to calibrate the leakage current measuring network is successfully designed by using high frequency voltage source. It has been verified that the measurement results consist with the requirements of IEC 60990.
Keywords :
IEC standards; calibration; electric current measurement; leakage currents; measurement standards; IEC 60990; calibration; frequency voltage source; leakage current measuring network; leakage current tester; Current measurement; Frequency measurement; IEC standards; Impedance; Impedance measurement; Leakage currents; Voltage measurement; Leakage current tester; leakage current expectations; measuring network;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location :
Rio de Janeiro
ISSN :
0589-1485
Print_ISBN :
978-1-4799-5205-2
Type :
conf
DOI :
10.1109/CPEM.2014.6898505
Filename :
6898505
Link To Document :