DocumentCode
236541
Title
Accurate high-current DC current ratio measurements
Author
Rietveld, Gert ; van der Beek, Jan ; Houtzager, Ernest
Author_Institution
VSL, Delft, Netherlands
fYear
2014
fDate
24-29 Aug. 2014
Firstpage
610
Lastpage
611
Abstract
A setup has been developed for the accurate calibration of DC current ratios for DC currents up to 600 A. The setup is based on a DC current comparator and suitable for the calibration of DC current ratio measurement devices up to 100 A primary current. For higher primary currents, multiple turns of the primary conductor are made through the device under test. It has been verified that for well-designed devices this adds less than 1 part in 106 to the measurement uncertainty. A preliminary evaluation indicates that the total uncertainty of the setup is better than 5 parts in 106 in current ratio for primary currents up to 600 A.
Keywords
calibration; conductors (electric); current comparators; electric current measurement; measurement uncertainty; DC current comparator; DC current ratio measurement device; calibration; current 600 A; device under test; measurement uncertainty; precision measurement; primary conductor; Bridge circuits; Calibration; Current measurement; Electrical resistance measurement; Resistors; Temperature measurement; Uncertainty; DC current; current comparator; current measurements; current scaling; precision measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location
Rio de Janeiro
ISSN
0589-1485
Print_ISBN
978-1-4799-5205-2
Type
conf
DOI
10.1109/CPEM.2014.6898533
Filename
6898533
Link To Document