Title :
A detailed analysis of the effect of dead time on harmonic distortion in a class D audio amplifier
Author :
Koeslag, F. ; du Mouton, H.T. ; Beukes, H.J. ; Midya, P.
Abstract :
This paper presents an analytical method for determining the effect of dead time on harmonic distortion in a class D audio amplifier. The analysis is based on the well established double Fourier series, providing accurate analytical solutions to the pulse width modulated spectra under natural sampling. The proposed analytical model differs from that of previous work in the sense that the precise contribution of each separate component can be determined, i.e. the fundamental component, baseband, carrier and sideband harmonics.
Keywords :
Fourier series; audio-frequency amplifiers; harmonic distortion; pulse width modulation; sampling methods; class D audio amplifier; dead time effect; double Fourier series; harmonic distortion; natural sampling; pulse width modulated spectra; Harmonic analysis; Harmonic distortion; Inductors; Leg; Pulse amplifiers; Pulse width modulation; Pulse width modulation inverters; Rails; Space vector pulse width modulation; Voltage; Class D Audio; Dead Time; Total Harmonic Distortion;
Conference_Titel :
AFRICON 2007
Conference_Location :
Windhoek
Print_ISBN :
978-1-4244-0987-7
Electronic_ISBN :
978-1-4244-0987-7
DOI :
10.1109/AFRCON.2007.4401640