DocumentCode :
236629
Title :
Improvements to the MSL mains-frequency power standard
Author :
Stewart, T.J. ; Jones, Ken
Author_Institution :
Meas. Stand. Lab. of New Zealand (MSL), Callaghan Innovation, Lower Hutt, New Zealand
fYear :
2014
fDate :
24-29 Aug. 2014
Firstpage :
724
Lastpage :
725
Abstract :
A bridge-based mains frequency power standard has been operated at MSL for the last 16 years. Over this time there have been some improvements to the bridge components and some refinements to the procedures used for calibrating the bridge. These changes have reduced the standard uncertainty from 19 μW/W to 11 μW/W at unity power factor.
Keywords :
calibration; frequency standards; measurement uncertainty; power factor measurement; power measurement; MSL main-frequency power Standard; bridge-based main frequency power standard; calibration; standard uncertainty; unity power factor; Bridge circuits; Current measurement; Reactive power; Standards; Temperature measurement; Uncertainty; Voltage measurement; Energy standard; mains-frequency; power bridge; power standard; var; watt-hour meter calibration; wattmeter;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location :
Rio de Janeiro
ISSN :
0589-1485
Print_ISBN :
978-1-4799-5205-2
Type :
conf
DOI :
10.1109/CPEM.2014.6898590
Filename :
6898590
Link To Document :
بازگشت