Abstract
This paper describes calibration methods of current comparators (CCs) and balancing current generators (BCGs) accompanied with them, for establishing a high-accuracy ac current ratio standard up to 4 kHz. The CC calibration is explained mathematically according to the self-calibration procedure that NMIJ has been exploiting. The BCG calibration is based on measurement of the conversion ratio. The technique with a CC and CT is unique in terms of the fact that the uncertainty can be ignored against the CT calibration.
Keywords
calibration; current comparators; electric current measurement; mathematical analysis; measurement standards; BCG; CC; NMIJ; balancing current generator; calibration method; conversion ratio measurement uncertainty; current comparator; high-accuracy AC current ratio standard; mathematical analysis; Calibration; Current measurement; Current transformers; IEC standards; Uncertainty; Windings; Current transformer; ac current ratio standards; current comparator; self calibration;