• DocumentCode
    236640
  • Title

    Accurate measurement of AC voltage in audio band using Agilent 3458A sampling capability

  • Author

    Lapuh, Rado ; Voljc, Bostjan ; Lindic, Matjaz

  • Author_Institution
    SIQ - Slovenian Inst. of Quality & Metrol., Ljubljana, Slovenia
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    740
  • Lastpage
    741
  • Abstract
    The paper describes frequency dependence correction of the Agilent 3458A DMM in DCV sampling mode. The biggest error source identified is the input filter roll-off, which was measured and evaluated with an asynchronous sampling technique using phase sensitive sine fit algorithm. Corrected response is flat within 50 μV/V in the whole audio frequency band.
  • Keywords
    digital multimeters; electric current measurement; sampling methods; voltage measurement; AC voltage measurement; Agilent 3458A DMM; Agilent 3458A sampling capability; DCV sampling mode; asynchronous sampling technique; audio frequency band; error source; frequency dependence correction; input filter roll-off; phase sensitive sine fit algorithm; Apertures; Bandwidth; Frequency conversion; Frequency dependence; Frequency measurement; Uncertainty; Voltage measurement; Measurement of ac voltage; PSFE algorithm; asynchronous sampling; audio band; calibration; correction; frequency dependence; nput filter roll-off; uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898598
  • Filename
    6898598