DocumentCode
236640
Title
Accurate measurement of AC voltage in audio band using Agilent 3458A sampling capability
Author
Lapuh, Rado ; Voljc, Bostjan ; Lindic, Matjaz
Author_Institution
SIQ - Slovenian Inst. of Quality & Metrol., Ljubljana, Slovenia
fYear
2014
fDate
24-29 Aug. 2014
Firstpage
740
Lastpage
741
Abstract
The paper describes frequency dependence correction of the Agilent 3458A DMM in DCV sampling mode. The biggest error source identified is the input filter roll-off, which was measured and evaluated with an asynchronous sampling technique using phase sensitive sine fit algorithm. Corrected response is flat within 50 μV/V in the whole audio frequency band.
Keywords
digital multimeters; electric current measurement; sampling methods; voltage measurement; AC voltage measurement; Agilent 3458A DMM; Agilent 3458A sampling capability; DCV sampling mode; asynchronous sampling technique; audio frequency band; error source; frequency dependence correction; input filter roll-off; phase sensitive sine fit algorithm; Apertures; Bandwidth; Frequency conversion; Frequency dependence; Frequency measurement; Uncertainty; Voltage measurement; Measurement of ac voltage; PSFE algorithm; asynchronous sampling; audio band; calibration; correction; frequency dependence; nput filter roll-off; uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location
Rio de Janeiro
ISSN
0589-1485
Print_ISBN
978-1-4799-5205-2
Type
conf
DOI
10.1109/CPEM.2014.6898598
Filename
6898598