Abstract :
The binary inductive voltage dividers (BIVD) have been designed as the 2:1 ratio reference at frequencies up to 1MHz. In this paper, the BIVDs are described in detail together with the calibration of their ratio errors by a substitution method. The measurement results of the BIVDs have also been given at frequencies from 1 kHz to 1MHz.
Keywords :
calibration; inductance measurement; voltage dividers; voltage measurement; BIVD; binary inductive voltage divider; frequency 1 kHz to 1 MHz; self-calibration; substitution method; Calibration; Frequency conversion; Frequency measurement; Inductance measurement; Measurement uncertainty; Voltage measurement; Windings; Binary inductive voltage divider; measurement uncertainties; millivolt ac voltage; self-calibrated; substitution method;