• DocumentCode
    2367270
  • Title

    Increased accuracy in large scale sewer flow mean velocity measurements using an array of ultrasonic velocity transducers

  • Author

    Hughes, A.W. ; Longair, I.M. ; Ashley, R.M. ; Kirby, K.

  • Author_Institution
    Abertay Dundee Univ, UK
  • fYear
    1995
  • fDate
    34793
  • Firstpage
    42430
  • Lastpage
    42432
  • Abstract
    Velocity profile information over the whole cross-section of the flow is required, in order to enable the computation of an improved mean velocity of flow. A new prototype system developed by the authors makes use of an array of ultrasonic Doppler transducers to meet this need in large sewers. The transducers provide multiple velocity measurements across the whole section of the sewer´s flow to provide a velocity profile. The velocity profile, provided by the array of Doppler velocity transducers, can thus be used to improve the accuracy of mean velocity of flow measurements in large sewers
  • Keywords
    Doppler shift; flow measurement; ultrasonic transducers; velocity measurement; water treatment; Doppler shift; US Doppler velocity transducers; accuracy; flow measurements; large scale sewer; velocity measurements; velocity profile;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Intelligent Measuring Systems for Control Applications, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19950438
  • Filename
    475013