• DocumentCode
    2368251
  • Title

    Machinable Rogowski coil, design and calibration

  • Author

    Ramboz, John D.

  • fYear
    1995
  • fDate
    24-26 April 1995
  • Firstpage
    329
  • Abstract
    Rogowski coils are special types of mutual inductors often used to measure high ac and transient currents. Traditional designs are reviewed. The significant sources of error associated with a particular coil design are identified and examined. A “machinable Rogowski coil” is introduced and discussed. The reasoning behind critical design choices are discussed. The improved performance of the machinable coil is compared to that of other designs. Test and calibration methods are shown and discussed
  • Keywords
    Calibration; Coils; Conductors; Current measurement; Inductance; Inductors; Instruments; Noise measurement; Voltage measurement; Wounds;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1995. IMTC/95. Proceedings. Integrating Intelligent Instrumentation and Control., IEEE
  • Conference_Location
    Waltham, MA, USA
  • Print_ISBN
    0-7803-2615-6
  • Type

    conf

  • DOI
    10.1109/IMTC.1995.515151
  • Filename
    515151