DocumentCode
2368251
Title
Machinable Rogowski coil, design and calibration
Author
Ramboz, John D.
fYear
1995
fDate
24-26 April 1995
Firstpage
329
Abstract
Rogowski coils are special types of mutual inductors often used to measure high ac and transient currents. Traditional designs are reviewed. The significant sources of error associated with a particular coil design are identified and examined. A “machinable Rogowski coil” is introduced and discussed. The reasoning behind critical design choices are discussed. The improved performance of the machinable coil is compared to that of other designs. Test and calibration methods are shown and discussed
Keywords
Calibration; Coils; Conductors; Current measurement; Inductance; Inductors; Instruments; Noise measurement; Voltage measurement; Wounds;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference, 1995. IMTC/95. Proceedings. Integrating Intelligent Instrumentation and Control., IEEE
Conference_Location
Waltham, MA, USA
Print_ISBN
0-7803-2615-6
Type
conf
DOI
10.1109/IMTC.1995.515151
Filename
515151
Link To Document