DocumentCode :
2369082
Title :
Current Sensor Fault Detection by Bilinear Observer for a Doubly Fed Induction Generator
Author :
Rothenhagen, Kai ; Fuchs, Friedrich W.
Author_Institution :
Kiel Univ.
fYear :
2006
fDate :
6-10 Nov. 2006
Firstpage :
1369
Lastpage :
1374
Abstract :
A bilinear observer is presented to detect current sensor faults in a doubly fed induction generator. The state space model is derived from the voltage equations of stator and rotor. The bilinear behaviour of induction machines and its influence on the state space model is discussed. An open loop model suffers from model and parameter uncertainty. A closed loop observer is shown to greatly reduce these effects. Observer pole placement is mentioned. Feeding back rotor currents only, the observer becomes independent from stator current measurements. The resulting free residuals can be used for sensor fault detection. The observer is validated by laboratory experiment
Keywords :
asynchronous generators; electric sensing devices; fault diagnosis; feedback; observers; pole assignment; rotors; state-space methods; stators; bilinear observer; closed loop observer; current sensor fault detection; doubly fed induction generator; open loop model; parameter uncertainty; pole placement; rotor; state space model; stator; voltage equations; Equations; Fault detection; Induction generators; Induction machines; Rotors; State feedback; State-space methods; Stators; Uncertain systems; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
IEEE Industrial Electronics, IECON 2006 - 32nd Annual Conference on
Conference_Location :
Paris
ISSN :
1553-572X
Print_ISBN :
1-4244-0390-1
Type :
conf
DOI :
10.1109/IECON.2006.347390
Filename :
4153252
Link To Document :
بازگشت