DocumentCode :
2369341
Title :
Improvements in the CW evaluation of mode-stirred chambers
Author :
Ladbury, John M. ; Koepke, Galen H. ; Camel, Dennis G.
Author_Institution :
Nat. Inst. of Stand. & Technol., Boulder, CO, USA
fYear :
1997
fDate :
18-22 Aug 1997
Firstpage :
33
Lastpage :
37
Abstract :
The authors present methods for improving the reliability of measurements made in a mode-stirred chamber. The combination of improved instrumentation and a larger paddle resulted in measurements that were significantly more reproducible (±1 dB) than previous measurements. They also give a simple model that is capable of describing the characteristics of a mode-stirred chamber at any frequency using only two parameters
Keywords :
electromagnetic compatibility; field strength measurement; measurement errors; test facilities; CW evaluation; EMC testing; instrumentation; measurement reliability; mode-stirred chambers; Antenna measurements; Electromagnetic measurements; Fluctuations; Frequency; Instruments; NIST; Power measurement; Q factor; Reproducibility of results; Transmitting antennas;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 1997. IEEE 1997 International Symposium on
Conference_Location :
Austin, TX
Print_ISBN :
0-7803-4140-6
Type :
conf
DOI :
10.1109/ISEMC.1997.667536
Filename :
667536
Link To Document :
بازگشت