Abstract :
In this paper, a digital-analog control scheme for a three-phase shunt active power filter is presented. Three algorithms for determining the active filter compensating current under several mains conditions are investigated and compared. The three single-phase method, the power balance concept and the extension of the p-q algorithm gives good steady-state and transient performances for both harmonics and reactive power compensation under balanced sinusoidal or nonsinusoidal conditions. However the p-q algorithm is still ineffective under unbalanced voltage conditions. The three-phase digital PLL system allows to operate satisfactorily in a wide range of mains frequencies. The close agreement between simulation and experimental results proves the validity of the optimized DC capacitor design and the feasibility of the proposed control methods
Keywords :
power system control; PLL system; control algorithms; control design; digital-analog control scheme; harmonics compensation; p-q algorithm; power balance concept; reactive power compensation; steady-state and transient performance; three single-phase method; three-phase shunt active power filters; transient performance;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Electronics and Variable Speed Drives, 1998. Seventh International Conference on (Conf. Publ. No. 456)
Conference_Location :
London
ISSN :
0537-9989
Print_ISBN :
0-85296-704-7
Type :
conf
DOI :
10.1049/cp:19980492
Filename :
732005
Link To Document :
بازگشت