Abstract :
When designing an inverter-fed PM-motor, one is quite free to choose a number of poles which utilizes the machine in a good way. A common rule of thumb is to choose a high pole-number for low-speed motors and vice versa, but there are no sharp borderlines between the different areas. This paper gives a suggestion regarding the pole-number for a desired power and speed of the motor