Abstract :
As a rapid, noncontact, and nondestructive technology, magnetostrictive guided waves have been widely used for the quality inspection of pipes and stay cables. Traditionally, a single-frequency signal with a high amplitude and a long pulse duration is used to increase the excitation energy and detection distance. However, the longer the pulse duration of a single-frequency signal is, the lower the resolution of adjacent defects and the accuracy of defect location will be. A novel method of addressing this problem is proposed in this paper. An encoded multifrequency excitation signal, whose frequency range is selected from a calculated dispersion curve, is used to excite the guided wave. After passing through the signal-conditioning board, the detected defect signals are sampled, averaged, and then filtered using a matched filter. In this manner, the pulse width of echoes can be greatly compressed. Our experimental results demonstrate that our proposed method can improve the resolution of adjacent defects and the accuracy of defect location in the propagation direction of the magnetostrictive guided wave.
Keywords :
automatic optical inspection; cables (mechanical); magnetostriction; matched filters; mechanical engineering computing; nondestructive testing; pipes; quality control; signal conditioning circuits; signal detection; signal sampling; adjacent defect resolution; defect location accuracy; detected defect signal filtering; detected defect signal sampling; dispersion curve; echo pulse width compression; magnetostrictive guided wave nondestructive testing method; matched filter; multifrequency excitation pulse signal; multifrequency excitation signal encoding; pipes; quality inspection; signal conditioning board; stay cables; Magnetostriction; Magnetostrictive devices; Nondestructive testing; Sensors; Signal resolution; Adjacent defect resolution; defect location; magnetostrictive guided wave; multifrequency signal; nondestructive testing; nondestructive testing.;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2014.2324812
Filename :
6822624
Link To Document :
بازگشت