• DocumentCode
    2374730
  • Title

    Results of the quartz crystal measurement data obtained at the leadless resonator measurement workshop held in Japan

  • Author

    Oomura, Yoslumasa ; Watanabe, Yasuaki ; Koyama, Mitsuaki

  • Author_Institution
    Tokyo Metropolitan Univ., Japan
  • fYear
    1993
  • fDate
    2-4 Jun 1993
  • Firstpage
    614
  • Lastpage
    619
  • Abstract
    The authors present the results of a workshop held at Tokyo Metropolitan University for the purpose of investigating the measurement method and specifications for surface-mounted leadless crystal units, and obtaining actual data. It has been shown that unifying the basic specifications (PI circuit method) and the measurement software algorithm (proposed IEC specification) allows high-accuracy measurement to be conducted, even if different fixtures and measurement instruments are used
  • Keywords
    crystal resonators; electric variables measurement; equivalent circuits; quartz; surface mount technology; IEC specification; PI circuit method; SiO2; high-accuracy measurement; leadless resonator measurement; measurement instruments; measurement software algorithm; surface-mounted leadless crystal units; Calibration; Capacitance measurement; Electric variables measurement; Electrical resistance measurement; Frequency measurement; IEC standards; Impedance measurement; Inductance measurement; Instruments; Measurement standards;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Frequency Control Symposium, 1993. 47th., Proceedings of the 1993 IEEE International
  • Conference_Location
    Salt Lake City, UT
  • Print_ISBN
    0-7803-0905-7
  • Type

    conf

  • DOI
    10.1109/FREQ.1993.367451
  • Filename
    367451