DocumentCode
2375608
Title
Optical correlator notch filters for Fermilab debuncher betatron stochastic cooling
Author
Pasquinelli, Ralph J. ; Kells, William ; Peterson, David ; Marriner, John
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
fYear
1989
fDate
20-23 Mar 1989
Firstpage
694
Abstract
Optical correlator notch filters have been installed in the Fermilab Antiproton Debuncher ring. Their main function is the improvement of system signal-to-noise ratio without degradation of system gain and phase parameters. This is turn yields faster cooling times that are compatible with the more rapid antiproton production cycles proposed for future operation. A brief discussion of cooling techniques is presented, showing the importance of the filters. In addition, the actual hardware implementation and performance results are presented
Keywords
beam handling equipment; beam handling techniques; Fermilab Antiproton Debuncher ring; Fermilab debuncher betatron stochastic cooling; antiproton production cycles; degradation; phase parameters; signal-to-noise ratio; system gain; Band pass filters; Colliding beam accelerators; Cooling; Correlators; Hardware; Optical filters; Particle beams; Production; Signal to noise ratio; Stochastic processes;