DocumentCode
2375663
Title
FEM evaluation of performance of axial flux slotted permanent magnet machines
Author
Caricchi, F. ; Crescimbini, F. ; Santini, E. ; Santucci, C.
Author_Institution
Dept. of Electr. Eng., Rome Univ., Italy
Volume
1
fYear
1998
fDate
12-15 Oct. 1998
Firstpage
12
Abstract
Axial-flux permanent magnet machines with slotted windings exhibit a significant cogging torque due to the magnetic anisotropy of the stator. The same produces a harmonic content in machine back EMF. The paper introduces and discusses a simple and powerful FEM algorithm that gives a numerical evaluation of both cogging torque and back EMF. Parametric analysis leads to a machine design that most meets the requirements for low cogging torque and limited higher harmonic content in back EMF.
Keywords
harmonics; machine theory; magnetic anisotropy; permanent magnet machines; stators; torque; FEM algorithm; axial-flux slotted PM machines; cogging torque; harmonic content; machine back EMF; machine design; machine performance evaluation; numerical evaluation; parametric analysis; slotted windings; stator magnetic anisotropy; Algorithm design and analysis; Forging; Harmonic analysis; Iron; Machine windings; Magnetic analysis; Permanent magnet machines; Shape; Stators; Torque;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 1998. Thirty-Third IAS Annual Meeting. The 1998 IEEE
Conference_Location