DocumentCode :
2377500
Title :
Microwave non-invasive sensing of respiratory tidal volume
Author :
Massagram, Wansuree ; Lubecke, Victor M. ; Boric-Lubecke, Olga
Author_Institution :
Dept. of Comput. Sci. & IT, Naresuan Univ., Phitsanulok, Thailand
fYear :
2009
fDate :
3-6 Sept. 2009
Firstpage :
4832
Lastpage :
4835
Abstract :
This paper describes the use of Doppler radar to measure respiration rate and air volume. The respiratory volume is measured indirectly via chest wall position. Calibration of displacement to airflow prior to subject measurements and accurate chest wall position information enable mean differences of less than 10 ml; with standard deviation of the difference of 20 ml between radar and reference measurements.
Keywords :
Doppler radar; biomedical measurement; calibration; medical signal processing; pneumodynamics; Doppler radar; air volume; airflow; calibration; chest wall position; microwave noninvasive sensing; respiration rate; respiratory tidal volume; Humans; Microwaves; Monitoring, Physiologic; Radar; Respiratory Rate; Tidal Volume;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
Conference_Location :
Minneapolis, MN
ISSN :
1557-170X
Print_ISBN :
978-1-4244-3296-7
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2009.5332667
Filename :
5332667
Link To Document :