DocumentCode
2378237
Title
Utilization of a Measurement Based CAD Tool for Enhanced PA Design Investigations
Author
Sheikh, Aamir ; Lees, Jonathan ; Benedikt, J. ; Tasker, P.J.
Author_Institution
Cardiff Sch. of Eng., Cardiff Univ., Cardiff
fYear
2008
fDate
27-31 Oct. 2008
Firstpage
1671
Lastpage
1674
Abstract
This paper outlines the use of a measurement based waveform CAD tool for enhanced PA design. Two measurement based models have been used to simulate a complete Doherty power amplifier together with output matching. The output matching network and auxiliary bias were optimised to produce a region of high efficiency typical of Doherty power amplifiers. Through the incorporation of a large signal de-embedding network, the current and voltage waveforms were accessed at the current generator plane. This allowed for the confirmation of Doherty operation on an individual device basis. This powerful tool allows for further optimisation of power amplifiers using well established waveform design procedures, previously not possible at high power levels.
Keywords
CAD; microwave power amplifiers; CAD tool; Doherty power amplifier; current waveform; voltage waveforms; Design automation; High power amplifiers; Impedance measurement; Microwave measurements; Operational amplifiers; Power amplifiers; Power generation; Power measurement; Table lookup; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference, 2008. EuMC 2008. 38th European
Conference_Location
Amsterdam
Print_ISBN
978-2-87487-006-4
Type
conf
DOI
10.1109/EUMC.2008.4751795
Filename
4751795
Link To Document