Design of a robotic system for MRI-guided deep brain stimulation electrode placement
Author :
Cole, Gregory ; Pilitsis, Julie ; Fischer, Gregory S.
Author_Institution :
Worcester Polytech. Inst., Worcester, MA, USA
Abstract :
Deep brain stimulation (DBS) is a technique for influencing brain function though the use of implanted electrodes. Direct magnetic resonance (MR) image guidance during DBS insertion would provide many benefits; most significantly, interventional MRI can be used for planning, monitoring of tissue deformation, real-time visualization of insertion, and confirmation of placement. The accuracy of standard stereotactic insertion is limited by registration errors and brain movement during surgery. With real-time acquisition of high-resolution MR images during insertion, probe placement can be confirmed intra-operatively. Direct MR guidance has not yet taken hold because it is often confounded by a number of issues including: MR-compatibility of existing stereotactic surgery equipment and patient access in the scanner bore. The high resolution images required for neurosurgical planning and guidance require high-field MR (1.5-3 T); thus, any system must be capable of working within the constraints of a closed, long-bore diagnostic magnet. Currently, no technological solution exists to assist MRI guided neurosurgical interventions in an accurate, simple, and economical manner.We present the design of a robotic assistant system that overcomes these difficulties and promises safe and reliable electrode placement in the brain inside closed high-field MRI scanners. The robot performs the insertion under real-time 3 T MR image guidance. This paper described analysis of the workspace requirements, MR compatibility evaluation, and mechanism design.
Keywords :
brain; control system synthesis; image resolution; magnetic resonance imaging; medical robotics; robot dynamics; surgery; MR compatibility evaluation; MRI-guided deep brain stimulation electrode placement; brain movement; image resolution; magnetic resonance image guidance; mechanism design; neurosurgical guidance; neurosurgical planning; patient access; real-time visualization; registration errors; robotic assistant system design; standard stereotactic insertion; stereotactic surgery equipment; tissue deformation; workspace requirements; Brain stimulation; Electrodes; Magnetic resonance; Magnetic resonance imaging; Monitoring; Neurosurgery; Robots; Satellite broadcasting; Surgery; Visualization;
Conference_Titel :
Robotics and Automation, 2009. ICRA '09. IEEE International Conference on
Conference_Location :
Kobe
Print_ISBN :
978-1-4244-2788-8
Electronic_ISBN :
1050-4729
DOI :
10.1109/ROBOT.2009.5152343