Title :
The study of photoelectric facial blood flow volume Characteristic of heart blood stasis syndrome in premature coronary heart disease and the relations between it and TXB2, 6-K-PGF1α
Author :
Hu, Zhi-xi ; Zheng, Jing-hui
Author_Institution :
Hunan Univ. of Traditional Chinese Med., Changsha, China
Abstract :
Objective To investigate the photoelectric facial blood flow volume Characteristic of heart blood stasis syndrome (HBSS)in premature coronary heart disease(PCHD) and the relations between it and TXB2, 6-K-PGF1α. Methods 102 PCHD patients was divided to HBSS group(36 cases), phlegm syndrome(PS) groups (35 cases) and healthy control group(31 cases); facial photoplethysmography detected using GD-3 type device, TXB2, 6-K-PGF1α detected by enzymelinked immunosorbent assay and (ELISA) method. Results The Hb, He, Hf, Hb/Tab, Hf/Hb were significantly lower (P<;0.01) in HBSS group compared with the control group; The Hb, He, Hf and Hf/Hb was significantly lower (P<;0.01) in PS group compared with the control group; The Hb, Hb/Tab decreased significantly (P<;0.01) in HBSS group compared with PS group; The content of Hb was lowest in HBSS group, and then the PS group and the control group; The content of TXB2 was higher in HBSS group than other 2 groups, The 6-K-PGF1α was lower than other 2 groups (P<;0.01).With the dominant wave of photoplethysmography increased, TXB2 values were gradually decreased, 6-K-PGF1α values was gradually increased; There is a significant difference between low volatility group with high volatility group. There is a negative correlation with Hb and TXB2, a positive correlation with Hb and 6-K-PGF1α. Conclusion Cardiac dysfunction and reduced of arterial compliance is one of the basic pathological changes of HBSS; there is a negative correlation with Hb and TXB2, a positive correlation with Hb and 6-K-PGF1α. The Hb accurate responses to vasomotor vascular status and changes of bioactive substances in vivo. The 3 can be regarded as a diagnosis indicator of HBSS in PCHD.
Keywords :
blood vessels; cardiovascular system; diseases; enzymes; haemodynamics; molecular biophysics; photoelectricity; photoplethysmography; volume measurement; 6-K-PGF1α; ELISA; HBSS; PCHD; TXB2; arterial compliance; enzymelinked immunosorbent assay; facial photoplethysmography; heart blood stasis syndrome; phlegm syndrome; photoelectric facial blood flow volume; premature coronary heart disease; 6-K-PGF1α; TXB2; heart blood stasis syndrome (HBSS); phlegm syndrome(PS); photoelectric facial blood flow volume; premature coronary heart disease(PCHD);
Conference_Titel :
Bioinformatics and Biomedicine Workshops (BIBMW), 2010 IEEE International Conference on
Conference_Location :
Hong, Kong
Print_ISBN :
978-1-4244-8303-7
Electronic_ISBN :
978-1-4244-8304-4
DOI :
10.1109/BIBMW.2010.5703889